Infinium Global Screening Array-24 (Infinium GSA-24) Genotyping Service

CD Genomics provides high-throughput, cost-effective SNP genotyping using the Infinium Global Screening Array-24 BeadChip. This platform is designed for population genetics, genome-wide association studies (GWAS), pharmacogenomics, and precision medicine research, delivering accurate results across diverse global populations.

Our Infinium GSA-24 service supports projects with large sample sizes and tight deadlines, offering:

  • ~654,000 fixed markers with up to 100,000 custom add-ons.
  • Multi-ethnic genome coverage with high imputation accuracy across 26 populations.
  • 3-day streamlined workflow with weekly throughput of up to 5,760 samples.
  • Consistent performance with >99% call rates and >99.9% reproducibility.
Sample Submission Guidelines

Infinium Global Screening Array-24 BeadChip key advantages illustration

✅For GWAS and population genetics
✅High-throughput, cost-efficient service
✅Optimized global SNP coverage with Infinium technology
✅Fast, reproducible genotyping with >99% call rates

Table of Contents

    Overview – What Is Infinium GSA-24?

    The Infinium Global Screening Array-24 (Infinium GSA-24) is a high-density genotyping platform developed by Illumina for large-scale genetic research. It delivers reliable, reproducible data at a lower cost and faster turnaround compared with sequencing, making it a preferred choice for studies requiring thousands of samples.

    Unlike sequencing, which is discovery-driven, the Infinium GSA-24 focuses on known, clinically relevant genetic variants. Each BeadChip processes 24 DNA samples simultaneously and interrogates ~654,000 markers, with the flexibility to add up to 100,000 custom SNPs. This balance of fixed genome-wide coverage and customizable content ensures that the platform can be tailored to diverse study objectives.

    Over 15 million samples worldwide have been processed using the Infinium GSA family of arrays, establishing it as one of the most trusted tools in human genetics and translational research.

    Specifications

    Parameter Details
    Assay Type Infinium HTS format microarray
    Automation Compatible with automated array loader, liquid handling robots
    DNA Input 200 ng per sample
    Instrumentation iScan System
    Species Human DNA
    Marker Count ~654,027 fixed markers (plus up to 100K custom add-ons)
    Sample Capacity 24 samples per array
    Throughput Up to ~5,760 samples per week
    Variant Types SNPs, structural variants, CNVs

    Advantages of Infinium GSA-24

    High throughput

    – 24 samples per BeadChip with weekly capacity up to ~5,760 samples.

    Fast turnaround

    – streamlined Infinium HTS workflow delivers results in ~3 days.

    Robust accuracy

    – >99% call rates and 99.9% reproducibility across diverse sample types.

    Global relevance

    – optimized for high imputation accuracy across 26 populations from the 1000 Genomes Project.

    Clinical utility

    – curated variants from ClinVar, NHGRI-GWAS, PharmGKB, and ExAC databases.

    Pharmacogenomics-ready

    – comprehensive coverage of ADME genes and HLA loci.

    Broad sample compatibility

    – supports DNA from blood, saliva, buccal swabs, and FFPE tissue.

    Flexible customization

    – option to add up to 100,000 project-specific markers via DesignStudio.

    Workflow

    Figure: Schematic illustration of the Infinium GSA-24 genotyping workflow. DNA samples are processed through hybridization, scanning, and data analysis in a streamlined process.

    The Infinium GSA-24 workflow is based on Illumina’s Infinium HTS chemistry, designed for speed and reproducibility. Each step is optimized to minimize hands-on time and maintain high data quality.

    DNA preparation – genomic DNA is amplified and fragmented.

    Hybridization – DNA fragments bind to probes on the BeadChip.

    Imaging – the iScan system uses dual-laser optics to capture fluorescent signals.

    Genotyping – GenomeStudio software converts intensity data into SNP calls with >99% accuracy.

    This streamlined process enables large-scale population studies to be completed efficiently, with results ready for downstream association analysis and imputation.

    Data Analysis

    Analysis Level Process & Deliverables
    Basic QC & Genotyping
    • Chip-level QC metrics (call rate, signal intensity)
    • Sample QC (call rate, gender check, heterozygosity)
    • SNP genotyping calls generated using GenomeStudio
    Differential Analysis
    • Identification of SNPs with frequency differences between groups
    • Visualization of variant locations (chromosomal distribution)
    • Heatmaps showcasing differential SNP patterns
    Functional Annotation
    • GO and KEGG enrichment analysis of significant SNPs
    • Pathway-level insight into biological relevance
    Advanced Genetic Analysis
    • GWAS for variant-trait associations
    • Family linkage mapping in pedigrees
    • CNV detection via LRR and BAF deviation
    • Detection of uniparental disomy or mosaicism

    Data analysis workflow

    Delivery Summary

    ✅ High-confidence genotype data

    Expert-curated SNP calls for each sample, ready for downstream analysis.

    ✅ Quality control summary

    Includes overall sample call rates, per-locus cluster metrics, and sample performance assessment.

    ✅ Allele-frequency visualization

    B-allele frequency (BAF) and log R ratio (LRR) plots to reflect genotype distribution and detect CNVs where applicable.

    ✅ Concordance overview

    Summary of concordance against reference datasets or internal validation samples (e.g., rWGS or 1KG standards).

    ✅ Optional imputed dataset

    Genotype data projected onto additional variants via high-accuracy imputation when requested.

    Comparison of GSA-24 vs GDA-8

    Feature Infinium Global Screening Array-24 Kit Infinium Global Diversity Array-8 Kit
    Assay Type Infinium HTS format microarray Infinium LCG (8-sample format) microarray
    Sample Capacity per Array 24 samples 8 samples
    Marker Count ~654,027 fixed markers; up to 100K custom markers ~1.8 million markers, including extensive exonic and clinical content
    Info Content Focus Multi-ethnic genome-wide + curated clinical variants (ClinVar, PharmGKB, etc.) Enhanced clinical coverage including exons, rare variants, phenotype associations
    CNV Detection & Exonic Coverage Limited; primarily SNP genotyping High-resolution CNV detection with exonic emphasis; average resolution ~1.5 Mb
    Throughput High; scalable for population-level throughput Moderate; 8-sample format with high per-variant efficiency
    Ideal Use Cases GWAS, pharmacogenomics, disease risk profiling, multi-population studies Clinical research requiring deep coverage of disease genes, CNVs, and exonic variants
    Platform Compatibility Illumina iScan System with automation support Same iScan System compatible; goal of cost-effective per-variant yield

    Why Offer Both Services

    The GSA-24 service excels in high-throughput genotyping with broad, multi-ethnic variant coverage; ideal for large cohort studies.

    The GDA-8 service, with its denser marker set and enhanced exonic and clinical content, is better suited for deep, focused investigations—such as detailed variant discovery, CNV analysis, and translational/clinical research.

    Offering both enables CD Genomics to flexibly guide clients to the appropriate array based on their sample size, variant resolution needs, and study goals.

    Sample Requirements

    Parameter Requirement
    DNA Input Quantity ≥200 ng genomic DNA per sample
    DNA Concentration >50 ng/µL recommended
    Purity (OD260/280) 1.7–2.1, with clear electrophoresis bands
    DNA Integrity High molecular weight DNA >10 kb, minimal degradation
    Accepted Sample Types Blood, saliva, buccal swabs, fresh/frozen tissue, FFPE tissue
    Buffer/Storage TE buffer or nuclease-free water (ddH₂O)
    Container 1.5 mL microcentrifuge tube or 96-well plate, sealed with film
    Storage Conditions –20°C or below for long-term storage
    Transport Conditions 2–8°C with ice packs for local delivery; dry ice shipping (< –20°C) for long distance

    Applications of Infinium GSA-24 Genotyping

    The Infinium Global Screening Array-24 (Infinium GSA-24) is a versatile platform that supports a wide range of research applications:

    Population genetics & ancestry analysis

    Leverages multi-ethnic genome-wide markers for robust population structure studies and ancestry mapping

    Genome-Wide Association Studies (GWAS)

    Ideal for large-scale variant discovery linking genetic markers to complex traits and diseases

    Disease risk profiling & biomarker discovery

    Includes curated variants from ClinVar, NHGRI-GWAS catalog, and more for targeted risk analysis

    Pharmacogenomics & drug response research

    Features ADME-related markers and HLA/KIR content relevant to drug metabolism and personalized medicine

    Lifestyle and wellness characterization

    Supports trait mapping, wellness panels, and consumer genomics use cases with customizable boosters

    Translational and precision medicine initiatives

    Employed in clinical research for population stratification and therapeutic target validation

    High-throughput variant screening

    Enables flexible loading of large sample cohorts with an efficient 3-day workflow and automated processing

    FAQs – Infinium GSA-24 Genotyping Service

    Q1: How accurate is the Infinium Global Screening Array-24?

    The Infinium GSA24 demonstrates >99% concordance with reference whole-genome sequencing (rWGS) and benchmark datasets, with over 82% of assays achieving a Positive Predictive Value (PPV) of 100%—a standard aligned with clinical screening needs.

    Q2: Can the GSA-24 handle low-quality or low DNA input samples?

    Yes. The array maintains excellent performance even with low DNA inputs, preserving high call rates and reproducibility across sample types—a key advantage for studies using degraded or limited clinical samples.

    Q3: What types of research benefit most from the Infinium GSA-24?

    This platform supports a wide range of applications including SNP-based GWAS, disease risk profiling, pharmacogenomics (ADME/HLA), ancestry mapping, and translational studies—all powered by dense multi-ethnic coverage and curated clinical variants.

    Q4: What data do I receive after the run?

    We deliver high-density SNP genotype calls, QC metrics, optional imputed datasets, and detailed reliability assessments—ready for association studies or clinical-genomics pipelines.

    Q5: What is Positive Predictive Agreement (PPA), and why does it matter?

    PPA is the proportion of positive array results confirmed by gold-standard sequencing. Achieving PPV = 100% in over 82% of assays means the GSA-24 reliably identifies true positives—critical for confidence in variant interpretation.

    Q6: How many SNPs does Infinium GSA-24 include?

    The Infinium Global Screening Array-24 (GSA-24) features approximately 654,027 fixed markers, with the option to incorporate up to 100,000 customizable SNPs for tailored study needs.

    Q7: Is the GSA-24 accurate for pharmacogenomic markers?

    Yes. The GSA-24 includes curated pharmacogenomic (PGx) markers sourced from databases like PharmGKB and ClinVar, ensuring clinically relevant coverage for ADME, HLA, and immune-related genes.

    Case Study

    Developmental Validation of the Illumina Infinium Assay using the Global Screening Array (GSA) on the iScan System for use in Forensic Laboratories, bioRxiv , 2022.

    1. Background

    The study aimed to validate the Infinium Global Screening Array-24 v3.0 (GSA-24) for forensic applications, following SWGDAM and FBI Quality Assurance Standards (QAS). The goal was to test precision, sensitivity, reproducibility, and suitability for degraded or low-input DNA samples.

    2. Methods

    • The validation used DNA standards (NA12878, NA24385, NA24631) with inputs ranging from 200 ng down to 0.2 ng.
    • Evaluations included sensitivity, accuracy, repeatability, reproducibility, degradation, species specificity, contamination, and mixtures.
    • Genotype concordance was measured against NIST/Genome-in-a-Bottle (GIAB) reference data.

    3. Results

    • Call rates exceeded 99% for inputs ≥ 1 ng, and remained >95% at 0.2 ng.
    • Concordance rates versus GIAB references were consistently high (99.2% average). Within-sample replicates showed >99.8% reproducibility.
    • In mixture tests, profiles with a 3:1 ratio achieved 98.85% concordance and at 9:1 reached >99.99% concordance.
    • The array demonstrated robust performance even with challenging or degraded samples.

    Infinium GSA-24 validation call rates vs DNA input Figure caption: "Call rate and concordance across DNA input levels, demonstrating high performance of the GSA-24 v3.0 at inputs as low as 0.2 ng."

    4. Conclusions

    The validation confirms that Infinium GSA-24 v3.0 delivers high accuracy (>95% call rate at 0.2 ng), exceptional reproducibility (>99.8%), and robustness across degraded or mixed samples. These findings underscore its reliability for high-throughput research, forensics, precision medicine, and population-genetics applications.

    Demo

    demo result of Genotyping.

    For research purposes only, not intended for clinical diagnosis, treatment, or individual health assessments.
    Related Services
    Quote Request
    ! For research purposes only, not intended for clinical diagnosis, treatment, or individual health assessments.
    Contact CD Genomics
    Terms & Conditions | Privacy Policy | Feedback   Copyright © CD Genomics. All rights reserved.
    Top